Features
High quality, reliable and complete generating sets.
4; generating set carries a comprehensive test program
Every
which includes 25%, 50%, 75%, 100% , 110% loading test and
series protecting function (example: Low oil pressure , High
coolant temperature, over current/load etc.) check.
Easy for operation and maintenance.
Compact structure &high-strength chassis.
Base frame design incorporates an intergrade fuel tank for at
least 8 hours running (up to 650KVA).
The canopy body painting adopts the HenKel pretreatment
process and the base frame painting adopts sandblasting
+AkzoNobel powder, the paint warranty period can be 3 years.
High-performance free-maintenance batteries with isolation
switch.
Anti- vibration pads are mounted between the engine/alternator
feet and the base frame.
Top lifting point and steel base frame with forklift holes, easy for
transportation.
Compliance with international electrical safety standards.
Complete protection functions and safety labels.
A large number of matching optional to meet the needs of
various customers.
Engine Specifications
SPECIFICATION OPEN TYPE SILENT TYPE Engine model & manufacturer 2806A – E18TAG2
Model Genset PL – 650 P PL – 650 P Number Of Cylinder 6 Vertical In – Line
Power Output 650 Kva / 520 Kw 650 kva / 520 Kw Bore And Stroke 145.0 x 183.0 mm
Phase 3 ( Three) 3 ( Three) Displacement 18.100 Litres
Frequency 50 Hz @1500RPM 50 Hz @1500RPM Turbocharged and Air to Air Charge
Aspiration
Cooled
Voltage 220 / 380 V 220 / 380 V
Cycle 4 Stroke
Fuel Tank, Residential
Fuel Tank, Residential
Accessories Muffler, Batteries, Tools Cumbustion System Direct Injection
Muffler, Batteries, Tools Kit
Kit
Dimension LxWxT 3700 x 1535 x 2750 mm 5000 x 1800 x 2100 mm Compression Ratio 14.5 : 1
Weight 4453 Kg 5705 Kg Rotation Anti – Clockwise, viewed on Flywheel
Fuel tank 400 600 Total Lubricating Capacity 62 Liter
Cooling System Water Cooled
Also available in the following voltages:
Total Coolant Capacity 61 Litres
415/240V, 380/220V, 220/127V, 200/115V (According to customer requirements).
Rated Power/prime Power(PRP) : Fuel Consumption (L/H) 97.00(75% Load) / 132.0(100% Load)
Continuous running at variable load for unlimited periods with 10% overload available
for 1 hour in any 12 hour period, in accordance with ISO8528.
Standby Power/Emergency Standby Power (ESP): Heavy duty Perkins diesel engine
The maximum power available during a variable electrical power sequence, no overload Four stroke, water cooled, Turbocharged and Air to Air
on these ratings, in accordance with ISO 8528. Charge Cooled aspirated
Direct injection fuel system
Electric governor system
24V DC starter and charge alternator
Replaceable fuel filter and dry element air filter
Cooling radiator and fan
Starter battery(with lead acid) including rack and cables
Flexible fuel connection hoses
Industrial capacity exhaust silencer and steel bellows
Operation manuals and circuit diagram documents
Generator Silent Type Generator Open Type
Alternator Specifications
Alternator Manufacturer Stamford
Design Design Brushless Single Bearing, Revolving Field
Stator 2/3 Pitch
Rotor Single Bearing, Flexible Disc
Insulation System Class H
Standard Temperatur Rise 125 - 163°C Continous
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct Drive Centrifugar Blower Fan
AC Waveform Total Harmonic Distortion No Load <1.5% Non Distorting Balanced Linear Load <5%
Telephone Influence Factor ( TIF ) <50 per NEMA MGI – 22.43
Telephone Harmonic Factor ( THF ) <2%
Control System
DSE4520 ( Deepsea ) DSE4620 ( Deepsea ) DSE7320 ( Deepsea )
Suitable for > 250KVA Gen - sets Suitable for for all series Gen - sets
The Controller Display DSE4520 Control System DSE7320 Control System
Voltage between phases(L-L) √ √
Voltage between neutral and phase(L-N) √ √
Frequency √ √
3 Phase current √ √
Real power(kW) and apparent power(kVA) √ √
Power factor √ √
Engine speed √ √
Running hours √ √
Coolant temperature √ √
Oil pressure √ √
Battery voltage √ √
LCD alarm indication √ √
3 Phase mains (utility) sensing √ √
Emergency stop button √ √
High coolant temperature √ √
Low oil pressure √ √
Over current/load √ √
under/over speed, frequency & voltage √ √
Low/High battery voltage √ √
Low coolant level √ √
Generating Set Type
Genset Type Silent Genset Type Trailer Genset Type Open
Panel ATS / Synchrone
Panel ATS
Panel Synchrone
Sparepart
Module ( Deepsea ) Switch Temperatur Switch Oli Switch Aki Filter Solar
Filter Oli Filter Oli Filter Udara Speed Control AVR
Baterai Charger Camp Shaft Ampere Dynamo Stater Dynamo Bearing Generator