Run the following commands on each switch to verify the configuration:

It might take a few minutes for the LLDP information to update. If your command output is different from the output shown below, wait a few minutes, then run the command again.

cumulus@leaf01:mgmt:~$ net show lldp
LocalPort    Speed    Mode          RemoteHost     RemotePort
-----------  -------  ------------  ------------   ------------
swp1         1G       Default       spine01        swp1
swp2         1G       Default       leaf02         swp2
swp3         1G       Default       leaf02         swp3
cumulus@leaf02:mgmt:~$ net show lldp
LocalPort    Speed    Mode          RemoteHost     RemotePort
-----------  -------  ------------  ------------   ------------
swp1         1G       Default       spine01        swp2
swp2         1G       Default       leaf01         swp2
swp3         1G       Default       leaf01         swp3
cumulus@spine01:mgmt:~$ net show lldp
LocalPort    Speed    Mode          RemoteHost     RemotePort
-----------  -------  ------------  ------------   ------------
swp1         1G       Default       leaf01         swp1
swp2         1G       Default       leaf02         swp1

Run the following commands on each switch to show system information:

cumulus@leaf01:mgmt:~$ net show system
Hostname..............leaf01
Build.................Cumulus Linux 4.2.0
Uptime................0.00.23.740000
Model.................Cumulus VX
Memory................768MB
Disk..................6GB
Vendor Name...........Cumulus Networks
Part Number...........4.2.0
Base MAC Address......4:00:27:39:B1:12
Serial Number.........4:00:27:39:B1:12
Product Name..........VX