| Burner Input | Description |
| FuelFlwIn | Fuel Flow Input [pps] |
| GasPthCharIn | Gas Path Characteristics Input, 5x1 vector consisting of:
- W - gas path flow [pps] - ht - enthalpy [BTU/lbm] - Tt - Total Temperature [degR] - Pt - Total Pressure [psia] - FARc - Combusted Fuel to Air Ratio [frac] |
| Burner Output | Description |
| GasPthCharOut | Gas Path Characteristics Output, 5x1 vector consisting of:
- W - gas path flow [pps] - ht - enthalpy [BTU/lbm] - FARc - Combusted Fuel to Air Ratio [frac] - Pt - Total Pressure [psia] - Tt - Total Temperature [degR] |
| B_Data | Burner internal calculation data |
| Burner Mask Variable | Description |
| LHV_M | Fuel Lower Heating Value[BTU/lb] |
| dPnormBurner_M | Normalized Burner deltaP accross the burner[1 - psi/psi] |
| Eff_M | Burner Efficiency[frac] |