Thanks to visit codestin.com
Credit goes to github.com

Skip to content

Negative charge density values for rotated PF6- #1337

@FaustoMercierFanAccount

Description

Describe the bug
Running xTB calculations on a rotated PF6- molecule and requesting the .cub file yields negative charge density values

To Reproduce
Steps to reproduce the behaviour:

  1. happens with the following input PF6.xyz:
7
        -31.46269005
 P          0.0000060331       -0.0000041862       -0.0000004152
 F         -1.0866546602       -0.1246276129        1.2070092761
 F         -0.9779551894        1.0491512081       -0.7720726050
 F          0.7183772371        1.2397319910        0.7747440130
 F         -0.7183607105       -1.2397305117       -0.7747401691
 F          0.9779400896       -1.0491714806        0.7720741505
 F          1.0866433976        0.1246532309       -1.2070139887

and the xcontrol xcontrol.inp:

$cube
 step = 1.0
$write
 density=True
$end
  1. run xtb PF6.xyz --charge -1 --input xcontrol.inp
  2. the following output (converted to txt) shows 18 negative charge density values (searching -. in the file)
    density.txt

Additional context
This was observed for all grid resolutions I've tried (step = 1.0, 0.4, 0.1)
No negative values appear for this version of PF6-

7

P            0.000000        0.000000        0.000000
F            1.606000        0.000000        0.000000
F            0.000000        1.606000        0.000000
F            0.000000        0.000000       -1.606000
F            0.000000        0.000000        1.606000
F            0.000000       -1.606000       -0.000000
F           -1.606000        0.000000        0.000000

Metadata