Abstract
Professional Data Centers (PDC) quantity and their related energy consumption is in a continuous growing trend, with corresponding increments in the material demand. While the amount of energy during operation phase is normally measured, the amount of embedded energy and the total Cumulated Energy Demand (CED) is often overlooked. To estimate the total amount of energy and material demand, LCA is used to evaluate the CED and CMD (Cumulated Material Demand) of devices used in PDC. A server Unit typical of these facilities is analyzed using data from disassembly and elementary analysis to construct a model for LCA to estimate the CED and CMD of the device. Results indicate that most of the energy is consumed during the operation phase, which is dependent on the operating lifetime of the device. Uncertainties are present due to the quality of the databases used for the model.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
BITKOM: Betriebssicheres Rechenzentrum. BITKOM. Berlin, Germany (2013). Available online at https://www.bitkom.org/noindex/Publikationen/2013/Leitfaden/Betriebssicheres-Rechenzentrum/LF-Betriebssicheres-Rechenzentrum.zip, checked on 1/11/2018
Ciroth, A., Muller. S., Weidema, B., Lesage, P.: Empirically based uncertainty factors for the pedigree matrix in ecoinvent. In Int. J. Life Cycle Assess. 21(9), 1338–1348, checked on 1/11/2018 (2016)
Fichter, K., Hintemann, R.: The quantities of materials present in the equipment of data centers. J. Indus. Ecol. (2014). Available online at http://onlinelibrary.wiley.com/doi/10.1111/jiec.12155/epdf, checked on 1/11/2018
Fichter, K., Hintemann, R., Stobbe, L.: Materialbestand der Rechenzentren in Deutschland -. Eine Bestandsaufnahme zur Ermittlung von Ressourcen- und Energieeinsatz. Dessau-Roßlau, Germany (2010). Available online at https://www.umweltbundesamt.de/sites/default/files/medien/461/publikationen/4037.pdf, checked on 1/11/2018
Garnier, C.: Data Centre Life Cycle Assessment Guidelines. The Green Greed. Oregon, USA (2012). Available online at https://www.thegreengrid.org/en/resources/library-and-tools/236-Data-Center-Life-Cycle-Assessment-Guidelines, checked on 1/1/2018
Giegrich, J., Liebich, A., Lauwigi, C., Reinhardt J.: Indikatoren/Kennzahlen für den Rohstoffverbrauch im Rahmen der Nachhaltigkeitsdiskussion. Edited by UBA. UMWELTBUNDESAMT. Dessau-Roßlau, Germany (2012). Available online at http://www.uba.de/uba-info-medien/4237.html, checked on 1/11/2018
Hintemann, R.: Energy consumption of data centers continues to increase. 2015 update. Borderstep Institute. Berlin, Germany (3) (2016). Available online at https://www.borderstep.de/wp-content/uploads/2015/01/Borderstep_Energy_Consumption_2015_Data_Centers_16_12_2015.pdf, checked on 1/11/2018
Hintemann, R., Clausen, J.: Rechenzentren in Deutschland. Eine Studie zur Darstellung der wirtschaftlichen Bedeutung und der Wettbewerbssituation. Borderstep Institut. Berlin, Germany (2014). Available online at https://www.bitkom.org/noindex/Publikationen/2014/Studien/Studie-zu-Rechenzentren-in-Deutschland-Wirtschaftliche-Bedeutung-und-Wettbewerbssituation/Borderstep-Institut-Studie-Rechenzentren-in-Deutschland-05-05-20141.pdf, checked on 1/11/2018
hp: HP ProLiant DL380 Generation 5 (G5). QuickSpecs (2006). Available online at https://h20195.www2.hpe.com/v2/getpdf.aspx/c04282492.pdf?ver=4, checked on 1/11/2018
Rasmussen, N.: Calculating Space and power Density Requirements for Data Centers. Schneider Electric (2013). Available online at http://www.apc.com/salestools/NRAN-8FL6LW/NRAN-8FL6LW_R0_EN.pdf, checked on 1/10/2018
Szczepaniak, K., Hobohm, J.: Quantifizierung kritischer Rohstoffe in Rechenzentren als ressourcenrelevanter Bezug zur Grauen Energie. (Unveröffentlicht). Master Thesis. Tecnische Universität Hamburg, Hamburg, Germany (2017)
Whitehead, B., Andrews, D., Shah, A.: The life cycle assessment of a UK data centre. Int. J. Life Cycle Assess. 20(3), 332–349 (2015). https://doi.org/10.1007/s11367-014-0838-7
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Peñaherrera, F., Hobohm, J., Szczepaniak, K. (2019). LCA of Energy and Material Demands in Professional Data Centers: Case Study of a Server. In: Schebek, L., Herrmann, C., Cerdas, F. (eds) Progress in Life Cycle Assessment. Sustainable Production, Life Cycle Engineering and Management. Springer, Cham. https://doi.org/10.1007/978-3-319-92237-9_9
Download citation
DOI: https://doi.org/10.1007/978-3-319-92237-9_9
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-92236-2
Online ISBN: 978-3-319-92237-9
eBook Packages: EngineeringEngineering (R0)