Fix signal handling in logical replication workers
The logical replication worker processes now use the normal die()
handler for SIGTERM and CHECK_FOR_INTERRUPTS() instead of custom code.
One problem before was that the apply worker would not exit promptly
when a subscription was dropped, which could lead to deadlocks.
Author: Petr Jelinek <[email protected]>
Reported-by: Masahiko Sawada <[email protected]>