The Digital Optical Monitor script will periodically poll the optical power levels of each interface on a switch and generate syslog events when the transmit (Tx) or Receive (Rx) power levels change beyond the threshold. Optionally, SNMP v2c traps or v3 informs may be generated, as well.

License

lapierreni/dom

 
 

Repository files navigation

Digital Optical Monitor (dom.py)

Overview

The Digital Optical Monitor script will periodically poll the optical power levels of each interface on a switch and generate syslog events when the transmit (Tx) or Receive (Rx) power levels change beyond the threshold.
Optionally, SNMP v2c traps or v3 informs may be generated, as well.

License

This is licensed under the BSD3 license.

Requirements

  • net-snmp: ‘snmptrap’ MUST be in the PATH (included in EOS)
  • jsonrpclib: for access to Arista eAPI (included in EOS)

Installation / Configuration

Copy dom.py to a linux system or a directly to a switch. Edit the script and modify the switch eAPI configuration information and, optionally, the SNMP trap destination and required options.

    #
    # eAPI connection information:
    #   This must be configured to match the switch being monitored.
    #   See 'show management api http-commands' on your switch.
    #
    PROTOCOL = 'https'
    USERNAME = 'eapi'
    PASSWORD = 'admin'
    #HOSTNAME = '10.68.49.142'
    #HOSTNAME = '10.68.49.140'
    HOSTNAME = '10.81.108.137'
    PORT = 443

    #
    # SNMP_SETTINGS:
    #   Configure the snmptrap options to match your trap destination.
    #
    #     version: 2c|3
    #     seclevel: noAuthNoPriv|authNoPriv|authPriv
    #     authprotocol: MD5|SHA
    #     privprotocol: DES|SHA

    SNMP_SETTINGS = {'traphost': 'localhost',
                     'version': '3',
                     'secname': 'eosplus',
                     'seclevel': 'authPriv',
                     'authprotocol': 'MD5',
                     'authpassword': 'eosplus123',
                     'privprotocol': 'DES',
                     'privpassword': 'eosplus123'
                    }
    #SNMP_SETTINGS = {'traphost': 'localhost',
    #                 'community': 'eosplus',
    #                 'version': '2c',
    #                }

Make the script executable, then, optionally, configure it to start automatically on-boot.

SNMP configuration may be tested by using the hidden --test option which will send 1 sample trap/inform to the traphost.

./dom.py --test trap

Usage

    ./dom.py --help
    usage: dom.py [-h] [-c] [-r REBASE_POLL_LIMIT] [-t TOLERANCE]
                  [-p POLL_INTERVAL] [-d] [--no-syslog] [--snmp]

    Monitor interface optics send SNMP trap on changes in average Tx/Rx levels.

    optional arguments:
      -h, --help            show this help message and exit
      -c, --cumulative-average
                            Use cumulative average as base(Default: False)
      -r REBASE_POLL_LIMIT, --rebase-poll-limit REBASE_POLL_LIMIT
                            limit of consecutive polls generating logmessages,
                            before resetting the base (default=3)
      -t TOLERANCE, --tolerance TOLERANCE
                            variation (in dBm) which triggers messagesto be logged
                            (default=3)
      -p POLL_INTERVAL, --poll-interval POLL_INTERVAL
                            polling interval(default=10)
      -d, --debug           Send debug information to the console
      --no-syslog           Disable loging to syslog
      --snmp                Send SNMP traps/notices

Example:

./dom.py -d -t 1 -p 10 -c

Starting from within Arista EOS::

EOS eAPI must be configured on each monitored device. At a minimum, this requires:

EOS#configure terminal
EOS(config)#username eapiuser privilege 15 secret somepassword
EOS(config)#management api http-commands
EOS(config-mgmt-api-http-cmds)#no shutdown

To automatically start dom the switch on-boot, add the following:

EOS(config)#daemon dom
EOS(config-daemon-dom)#command /mnt/flash/dom.py --tolerance 2 --poll-interval 30
EOS(config)#end

Monitoring

EOS

EOS#show processes | include dom
10159  0.1  1.4 ?        S    03:21:23 00:00:00 rphm     -d -i --dlopen -p -f  -l libLoadDynamicLibs.so procmgr libProcMgrSetup.so --daemonize

Uninstall

EOS#config termintal
EOS(config)#no daemon dom
EOS(config)#end
EOS#delete flash:dom.py