I think we might want to s/createSocketTimeout/connectTimeout/
and use the existing GatewayServer.DEFAULT_CONNECT_TIMEOUT
to provide API backward compatibility. There are a few places that already have connectTimeout
but aren't wiring it through to socket connect.
@@ -90,6 +90,7 @@ public class CallbackClient implements Py4JPythonClient { | |||
protected final boolean enableMemoryManagement; | |||
|
|||
protected final int readTimeout; | |||
protected final int createSocketTimeout; |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
should this be connectTimeout
?
protected final int createSocketTimeout; | |
protected final int connectTimeout; |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
+1 for this renaming
@@ -150,7 +152,7 @@ public CallbackClient(int port, InetAddress address, long minConnectionTime, Tim | |||
public CallbackClient(int port, InetAddress address, long minConnectionTime, TimeUnit minConnectionTimeUnit, | |||
SocketFactory socketFactory, boolean enableMemoryManagement) { | |||
this(port, address, minConnectionTime, minConnectionTimeUnit, socketFactory, enableMemoryManagement, | |||
GatewayServer.DEFAULT_READ_TIMEOUT); | |||
GatewayServer.DEFAULT_READ_TIMEOUT, GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
GatewayServer.DEFAULT_READ_TIMEOUT, GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT); | |
GatewayServer.DEFAULT_READ_TIMEOUT, GatewayServer.DEFAULT_CONNECT_TIMEOUT); |
@@ -176,9 +178,9 @@ public CallbackClient(int port, InetAddress address, long minConnectionTime, Tim | |||
* Python program is closed. | |||
*/ | |||
public CallbackClient(int port, InetAddress address, long minConnectionTime, TimeUnit minConnectionTimeUnit, | |||
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout) { | |||
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout, int createSocketTimeout) { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout, int createSocketTimeout) { | |
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout, int connectTimeout) { |
this(port, address, null, minConnectionTime, minConnectionTimeUnit, socketFactory, enableMemoryManagement, | ||
readTimeout); | ||
readTimeout, createSocketTimeout); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
readTimeout, createSocketTimeout); | |
readTimeout, connectTimeout); |
public CallbackClient(int port, InetAddress address, long minConnectionTime, TimeUnit minConnectionTimeUnit, | ||
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout) { | ||
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout, int createSocketTimeout) { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
To avoid an API break, probably want to keep a constructor of the existing signature and use default socket connect timeout.
public CallbackClient(int port, InetAddress address, long minConnectionTime, TimeUnit minConnectionTimeUnit,
SocketFactory socketFactory, boolean enableMemoryManagement, int readTimeout) {
this(port, address, null, minConnectionTime, minConnectionTimeUnit, socketFactory, enableMemoryManagement,
readTimeout, GatewayServer.DEFAULT_CONNECT_TIMEOUT);
}
@@ -48,9 +48,10 @@ public class InstrPythonClient extends PythonClient { | |||
|
|||
public InstrPythonClient(Gateway gateway, List<Class<? extends Command>> customCommands, int pythonPort, | |||
InetAddress pythonAddress, long minConnectionTime, TimeUnit minConnectionTimeUnit, | |||
SocketFactory socketFactory, Py4JJavaServer javaServer, boolean enableMemoryManagement, int readTimeout) { | |||
SocketFactory socketFactory, Py4JJavaServer javaServer, boolean enableMemoryManagement, int readTimeout, | |||
int createSocketTimeout) { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
int createSocketTimeout) { | |
int connectTimeout) { |
and 🔭 constructor for API back compat
super(gateway, customCommands, pythonPort, pythonAddress, minConnectionTime, minConnectionTimeUnit, | ||
socketFactory, javaServer, enableMemoryManagement, readTimeout); | ||
socketFactory, javaServer, enableMemoryManagement, readTimeout, createSocketTimeout); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
socketFactory, javaServer, enableMemoryManagement, readTimeout, createSocketTimeout); | |
socketFactory, javaServer, enableMemoryManagement, readTimeout, connectTimeout); |
@@ -42,7 +42,8 @@ public void startServer2() { | |||
InstrClientServer server2 = new InstrClientServer(GatewayServer.DEFAULT_PORT + 5, | |||
GatewayServer.defaultAddress(), GatewayServer.DEFAULT_PYTHON_PORT + 5, GatewayServer.defaultAddress(), | |||
GatewayServer.DEFAULT_CONNECT_TIMEOUT, GatewayServer.DEFAULT_READ_TIMEOUT, | |||
ServerSocketFactory.getDefault(), SocketFactory.getDefault(), this, false, true); | |||
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT, ServerSocketFactory.getDefault(), |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
already have GatewayServer.DEFAULT_CONNECT_TIMEOUT
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT, ServerSocketFactory.getDefault(), | |
ServerSocketFactory.getDefault(), |
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT, ServerSocketFactory.getDefault(), | ||
SocketFactory.getDefault(), this, false, true); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
already have GatewayServer.DEFAULT_CONNECT_TIMEOUT
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT, ServerSocketFactory.getDefault(), | |
SocketFactory.getDefault(), this, false, true); | |
ServerSocketFactory.getDefault(), SocketFactory.getDefault(), this, false, true); |
@@ -98,7 +99,8 @@ public static void main(String[] args) { | |||
GatewayServer.turnLoggingOff(); | |||
CallbackClient callbackClient = new CallbackClient(GatewayServer.DEFAULT_PYTHON_PORT, | |||
GatewayServer.defaultIPv6Address(), CallbackClient.DEFAULT_MIN_CONNECTION_TIME, | |||
CallbackClient.DEFAULT_MIN_CONNECTION_TIME_UNIT, SocketFactory.getDefault(), false, 250); | |||
CallbackClient.DEFAULT_MIN_CONNECTION_TIME_UNIT, SocketFactory.getDefault(), false, 250, | |||
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
GatewayServer.DEFAULT_CREATE_SOCKET_CONNECTION_TIMEOUT); | |
GatewayServer.DEFAULT_CONNECT_TIMEOUT); |
Hey @HyukjinKwon! Thank you for taking the time to look at this. ContextThe reason I made a separate configuration came from my testing. Right now, if I set the connectTimeout to 10000 (10s), I consistently get errors (see attached video) This is confusing, as it appears I've connected to the gateway, sent commands, and during the execution of the command, I get this error. If I use the Potential Problem: On this line in the PythonClient, we set the SoTimeout as the However, on this line in GatewayServer, we use the connectTimeout. It's not clear to me why this is throwing exceptions when I set this value to > 0. Perhaps this is because we do not establish a keepalive (See below) Problem:Given the context, I'd be OK to use the connect timeout. But, I have concern that it would present other problems that I encountered above. In order to provide the right solution, I want to ask the following questions to help debug: Questions:
The combination of (1) and (2) would look like below, when we create sockets inside both our
Any clarification would greatly help me figure out the right solution! |
FYI, I am trying to make the tests stable first (e.g, reducing matrix first #519). I think we should make the CI green first .. |
I have not had time to back to this, but once I get the time to revisit, I will make the contribution |
Would be great if anyone finds some time to fix up the CI first. I will try around late this month too. |
Guys, sorry for the delay. Now the tests are fixed per #519. Would you mind rebasing this one please? |